Custom Array Observatory control elements for manage [[Array|Voyager array version]].
 
Custom Array Observatory control elements for manage [[Array|Voyager array version]].
 +
 +
 +
===Array===
 +
These commands manage multinode parallels actions for Array
  
 
[[File:DSArray.png]]
 
[[File:DSArray.png]]

Revision as of 13:03, 11 January 2021

In addition to the primary DragScript Actions, which do things like slewing the mount and running a sequence, DragScript elements can control other observatory functions, such as Starkeeper.it's companion product, Viking, which monitors and controls observatory I/O devices. Custom observatory control elements are also listed here, but they will not be of general interest.

Viking

These elements send commands to Voyager's companion product, Viking. Viking monitors and controls I/O devices in the observatory.

For more information on Viking, visit https://voyagerastro.com/products/viking

Dragscript-viking-2.11h.jpg

Viking Client

These commands connect to Viking and to Viking I/O cards. Refer to Viking Setup for further information on configuring Voyager to communicate with Viking.

Dragscript-viking-client.png

  • Viking Client Connect: Connect to the Viking software

Dragscript-viking-client-connect.png

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window
  • Viking Client Disconnect: Disconnect from the Viking software

Dragscript-viking-disconnect.png

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window
  • I/O Card Connect: Connect to Viking's I/O card

Dragscript-iocard-connect.png

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window
  • I/O Card Disconnect: Disconnect from Viking's I/O card:

Dragscript-iocard-connect.png

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window


Out Relays

Out Relay commands turn I/O relays connected to Viking on or off:

Dragscript-out-relays.png

  • Relay On: Command Viking to turn a relay on

Dragscript-relayon.jpg

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • OUT Number: Relay number to turn on. Enter 0 to turn on all the relays
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window
  • Relay Off: Command Viking to turn a relay off

Dragscript-relayoff.jpg

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • OUT Number: Relay number to turn off. Enter 0 to turn off all the relays
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window

Out Automation

Automation actions control I/O devices with three states: Open, Close and Stop. One piece of hardware that supports three states is the MyHome Bticino device https://www.bticino.com/solutions/home-automation/

The main use of this device is to control a motor that could be used, for example, to open or close a window shade, or stop it at a particular position. You may use this type of device in your observatory control to do something such as open and close a roll-off roof.

Dragscript-out-automation.png

  • Open Automation:

Dragscript-open-automation.jpg

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • Automation Number: Number of automation device to open
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window
  • Close Automation:

Dragscript-close-automation.jpg

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • Automation Number: Number of automation device to close
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window
  • Stop Automation: Stop the specified Viking automation's execution

Dragscript-stop-automation.png

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • Automation Number: Number of automation device to stop
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window


PWM Pulse Width Modulation

Dragscript-pwm.png

  • Activate PWM: Set the value of a pulse width modulation device and activate it:

Dragscript-pwm-open.jpg

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • PwM Number: Enter the number of the PWM device to control. Enter 0 to send this command to all PWM devices
  • Percentage: Set the PWM device to this level, specified as a percentage from 0-100%
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window
  • Deactivate PWM: Deactivate a pulse width modulation device:

Dragscript-deactivate-automation.jpg

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • PwM Number: Enter the number of the PWM device to deactivate. Enter 0 to send this command to all PWM devices
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window

DAC

This action is the setup for the DAC output to Viking.

Dragscript-dac-choice.jpg

  • Set DAC Output:

Dragscript-dac-setup.jpg

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • DAC Number: Enter the number of the DAC device to use. Enter 0 to send this command to all PWM devices
  • ADU Value: Analog to Digital Unit conversion factor. E.g., if the DAC can output 5VDC max and ADU resolution is 1024 ADU, 512 ADU is 2.5VDC
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window


In

These actions monitor inputs to Viking.

Dragscript-In.png

  • Wait High Level IN: Wait until the specified Viking input remains at a high level for the given amount of time:

Dragscript-in-high.jpg

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • IN Number: IN device to monitor for a high status
  • Is MyHome Bticino Input Type: If checked, the input to monitor is a MyHome Bticino device https://www.bticino.com/solutions/home-automation/
  • High for: Number of seconds for the device to remain in a high state to exit the wait
  • Timeout: Number of seconds to wait before timing out the wait
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window
  • Wait Low Level IN: Wait until the specified Viking input remains at a low level for the given amount of time:

Dragscript-wait-low.png

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • IN Number: IN device to monitor for a low status
  • Is MyHome Bticino Input Type: If checked, the input to monitor is a MyHome Bticino device https://www.bticino.com/solutions/home-automation/
  • Low for: Number of seconds for the device to remain in a Low state to exit the wait (TYPO: Field label should be "Low for:")
  • Timeout: Number of seconds to wait before timing out the wait
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window

Analog In

Analog In actions monitor analog input values to Viking.

Dragscript-analog-in.png

  • Wait Analog IN remain in range for: Wait until an analog input to Viking remains within the given range for the specified time:

Dragscript-analog-in-config.png

  • Client ID: Select the client ID to use when communicating to Viking. Currently this is pre-selected to Client ID #1
  • Analog IN Number: Analog IN device to monitor
  • Expected Range: Specify the minimum and maximum values of the desired range
  • In Range for: Amount of time in seconds the monitored Analog IN value must remain within the Expected Range for the wait to end
  • Timeout: Number of seconds to wait before timing out the wait
  • OK: Save the settings and close the window
  • Cancel: Discard changes and close the window


Custom Array Observatory

Custom Array Observatory control elements for manage Voyager array version.


Array

These commands manage multinode parallels actions for Array

DSArray.png

  • Custom Array Link: Link the Array establishing the communications between MASTER and SLAVE
  • Custom Array Unlink: Unlink the Array closing the communications between MASTER and SLAVE
  • Custom Array Setup Connect: Connect setup of each nodes in a parallelized way
    • DSArrayConnect.png
  • Custom Array Disconnect: Disconnect setup of each nodes in a parallelized way
    • DSArrayDisconnect.png
  • Custom Array Cooling: Cooling CCD camera of each nodes in a parallelized way
    • DSArrayCooldown.png
  • Custom Array Warmup: Warmup CCD camera of each nodes in a parallelized way
    • DSArrayWarmup.png
  • Custom Array Sequence: Run a Custom Array Sequence on the array
    • DSArraySequence.png